20230206_new_materil_emb/模块软件以及手册/ModScan32/example1.csv
2023-08-03 09:23:26 +08:00

2.5 KiB

1//
2// Example Test Script for ModScan Application
3//
4// Each Script entry consists of the following
5// comma delimited data fields:
6//
7// TEST NAME, NODE, FUNCTION, ADDRESS, LENGTH, DATA, CONTROL CODE
8//
9// Double slashes on the front of a line denote comments
10//
11// The following Control Codes may be used (i.e. last field on each line)
12// (Added March 2001)
13// New Test:
14//
15Analog Value Test,1,3,100,1,1000,%5
16//
17// First Test:
18// (DATA field consists of 32-bits and may be specified
19//
20Preset Multiple Coils,1,15,100,20,0xAAAAA,T
21//
22//
23// Second Test:
24//
25Verify Coil Status,1,1,100,20,0xAAAAA,T
26//
27// Third Test:
28//
29Verify Input Status,1,2,100,100,0,D
30//
31//
32// Forth Test:
33//
34Test Exception 2,1,3,100,1000,0,2
35//
36// Fifth Test:
37//
38Invalid Request,1,1,100,1,0,C
39//
40// Sixth Test:
41//
42Query Device 73,73,1,1,1,0,R
43//
44// Seventh Test:
45// (Each floating point number represents
46//
47Write Floats,1,16,100,6,1.00,\
48,2.00,3.00,,,,T
49//
50// Eighth Test:
51//
52Read Floats,1,3,100,6,1.00,\
53,2.00,3.00,,,,T
54//
55// END OF SCRIPT
56end